ETC/Elec Theatre Controls Automatic Load Control Relay
Designed for 0-10V fixtures and Ballasts

OUR PART #  ALCR-DIN


The ETC ALCR-DIN is a UL924 emergency lighting device that allows a single light, or zone of emergency lights, that are typically always on, to be controlled under everyday non-emergency circumstances, while forcing emergency lights on when normal power is lost or a fire alarm is activated. For increased safety and visibility, after a state of emergency is over and normal lighting is recovered, an optional delay (between 0-15 minutes) can be programmed to hold the emergency lighting state prior to returning to normal control as people exit or enter through normally dark areas. The DIN model is designed specifically for 0-10V fixtures and ballasts.  

ETC ALCR-DIN Features:

  • Forces emergency lighting on during loss of normal power
  • Monitors fire alarm or other external triggers to force emergency lighting on
  • Under normal conditions, the ALCR enables emergency lighting to track the state of normal lighting
  • Emergency lights can be forced to stay on for up to 15 minutes after emergency state is cleared
  • DIN rail version also supports 0-10V dimmed fixtures to be used in emergency lighting by forcing the control line to "full on"
  • UL Listed

ETC/Elec Theatre Controls Automatic Load Control Relay
Designed for 0-10V fixtures and Ballasts

OUR PART #  ALCR-DIN

Product Information:

The ETC ALCR-DIN is a UL924 emergency lighting device that allows a single light, or zone of emergency lights, that are typically always on, to be controlled under everyday non-emergency circumstances, while forcing emergency lights on when normal power is lost or a fire alarm is activated. For increased safety and visibility, after a state of emergency is over and normal lighting is recovered, an optional delay (between 0-15 minutes) can be programmed to hold the emergency lighting state prior to returning to normal control as people exit or enter through normally dark areas. The DIN model is designed specifically for 0-10V fixtures and ballasts.  

ETC ALCR-DIN Features:

  • Forces emergency lighting on during loss of normal power
  • Monitors fire alarm or other external triggers to force emergency lighting on
  • Under normal conditions, the ALCR enables emergency lighting to track the state of normal lighting
  • Emergency lights can be forced to stay on for up to 15 minutes after emergency state is cleared
  • DIN rail version also supports 0-10V dimmed fixtures to be used in emergency lighting by forcing the control line to "full on"
  • UL Listed
Add to Cart

We're sorry, only of this item available



Call a Sales Pro at for more information

Serving Contractors, Dealers, and Installers Since 1977

Contact: 1-800-828-0509 / Hours: Mon - Fri 7:00AM - 7:00PM