SurgeX PF420 Powerframe
Power Conditioner

OUR PART #  PF420-POWERFRAME


The SurgeX Powerframe 420 provides guaranteed surge protection and power conditioning for audio, video, broadcast and computer equipment.

Powerframe 420 units are compact 80 Amp load centers for multi-branch circuit applications. They offer four independent 20 Amp circuits in a 16" x 12" x 4" magnetic shielding NEMA enclosure and meet code for use at the service entrance, sub-panels and in ceiling plenums. The unit features both common mode and normal mode Impedance Tolerant EMI/RFI filtering for a comprehensive power conditioning solution.

SurgeX Advanced Series Mode technology is superior to conventional MOV circuitry or MOV-Hybrid designs and is completely non-sacrificial. Our zero let-through technology provides the most reliable protection available. It stops all surges up to 6,000 volts (unlimited surge current) without producing harmful side effects such as ground contamination or common-mode disturbances.

Features:

  • Magnetic shielding steel enclosure
  • Advanced Series Mode surge protection
  • Advanced Impedance Tolerant EMI/RFI filtering
  • Self-test circuit with visual indicator
  • 10-year warranty
  • Made in U.S.A.

Specifications:

  • Load Rating: 20 amps per circuit @ 120 volts (80 ampstotal)
  • Power Requirement (no load): 15 watts per circuit
  • Surge Let-Through Voltage (6000-volt surge): 0 volts
  • UL 1449 Adjunct Classification Test Results: 1000surges, 6000 volts, 3000 amps, B3 pulse; Measured suppressed voltage: 170volts; no failures.
  • Federal Guidelines: Grade A, Class 1, Mode 1 (CIDA-A-55818)
  • EMI/RFI Filter, Normal Mode (50-ohm load): 40 dB @100 kHz; 50 dB @ 300 kHz; 50 dB @ 3 MHz; 50 dB @ 30 MHz
  • EMI/RFI Filter, Common Mode (50-ohm load): 18 dB @300 kHz; 30 dB @ 1 MHz; 50 dB @ 5 MHz; 50 dB @ 20 MHz
  • Maximum Applied Surge Voltage: 6000 volts*
  • Maximum Applied Surge Current: Unlimited, due tocurrent limiting
  • Maximum Applied Surge Energy: Unlimited, due tocurrent limiting
  • Endurance (C62.41-1991 Category B3 pulses): 1kV>500,000; 3 kV>10,000; 6 kV>1000
  • Dimensions (H x W x D): 16" x 12" x 4" (40.6 x 30.5 x10.2 cm)
  • Weight: 30 lbs. (13.6 kg)
  • Temperature Range: 5º to 35º C
  • Humidity Range: 5% to 95% R.H., non-condensing
  • Agency Listings: ETL and cETL (UL 1449, 2nd edition; CSA C22.2 No.8-M1986,R2000)

SurgeX PF420 Powerframe
Power Conditioner

OUR PART #  PF420-POWERFRAME

Product Information:

The SurgeX Powerframe 420 provides guaranteed surge protection and power conditioning for audio, video, broadcast and computer equipment.

Powerframe 420 units are compact 80 Amp load centers for multi-branch circuit applications. They offer four independent 20 Amp circuits in a 16" x 12" x 4" magnetic shielding NEMA enclosure and meet code for use at the service entrance, sub-panels and in ceiling plenums. The unit features both common mode and normal mode Impedance Tolerant EMI/RFI filtering for a comprehensive power conditioning solution.

SurgeX Advanced Series Mode technology is superior to conventional MOV circuitry or MOV-Hybrid designs and is completely non-sacrificial. Our zero let-through technology provides the most reliable protection available. It stops all surges up to 6,000 volts (unlimited surge current) without producing harmful side effects such as ground contamination or common-mode disturbances.

Features:

  • Magnetic shielding steel enclosure
  • Advanced Series Mode surge protection
  • Advanced Impedance Tolerant EMI/RFI filtering
  • Self-test circuit with visual indicator
  • 10-year warranty
  • Made in U.S.A.

Specifications:

  • Load Rating: 20 amps per circuit @ 120 volts (80 ampstotal)
  • Power Requirement (no load): 15 watts per circuit
  • Surge Let-Through Voltage (6000-volt surge): 0 volts
  • UL 1449 Adjunct Classification Test Results: 1000surges, 6000 volts, 3000 amps, B3 pulse; Measured suppressed voltage: 170volts; no failures.
  • Federal Guidelines: Grade A, Class 1, Mode 1 (CIDA-A-55818)
  • EMI/RFI Filter, Normal Mode (50-ohm load): 40 dB @100 kHz; 50 dB @ 300 kHz; 50 dB @ 3 MHz; 50 dB @ 30 MHz
  • EMI/RFI Filter, Common Mode (50-ohm load): 18 dB @300 kHz; 30 dB @ 1 MHz; 50 dB @ 5 MHz; 50 dB @ 20 MHz
  • Maximum Applied Surge Voltage: 6000 volts*
  • Maximum Applied Surge Current: Unlimited, due tocurrent limiting
  • Maximum Applied Surge Energy: Unlimited, due tocurrent limiting
  • Endurance (C62.41-1991 Category B3 pulses): 1kV>500,000; 3 kV>10,000; 6 kV>1000
  • Dimensions (H x W x D): 16" x 12" x 4" (40.6 x 30.5 x10.2 cm)
  • Weight: 30 lbs. (13.6 kg)
  • Temperature Range: 5º to 35º C
  • Humidity Range: 5% to 95% R.H., non-condensing
  • Agency Listings: ETL and cETL (UL 1449, 2nd edition; CSA C22.2 No.8-M1986,R2000)